UF Implant

Internal Submerged System

UFII Implant

Internal Submerged System

DIO Implant has the world's best implant design and surface treatment technology.

SIGNATURE PRODUCT

UFII Internal Submerged System

Open Thread

A beültetési mélység a rögzítőeszköz elhelyezési ellenállásának csökkentésével állítható be.

Platform Switching

Since it has a platform switching structure,
stable prosthetic connection is possible.

Upper Thread

Tapered Thread, Initial Fixation

By applying a tapered thread to the straight body, the stress applied to the upper part of the fixture is effectively dispersed. The thread depth decreases upwards, reducing friction on the cortical bone.

Morse Tapered Contact
Connection

Tightness between fixture and abutment and load distribution are excellent.

Straight Body

Decrement of Bone Damage

The depth of the fixture is varied by changing the depth of the body part, and stable implantation is possible like a straight type in a fixture with a long depth.

Cutting edge

Self-tapping efficiency can be increased through sharp edges.

Tapered Body

Taper Guide Gradually

A kúp alkalmazásával a kezdeti behatolás gyenge fúrás esetén is könnyű, még akkor is, ha gyenge a csontminőség

Apex

The gentle round shape can reduce tissue damage caused by implants when used in the maxillary sinus.

Surface Treatment Feature

Hybrid Sand Blast & Acid Etched

DIO implants are manufactured in a Hybrid SLA (HSA) method that implements a rough surface.
The surface treatment technology of DIO implants increases the contact area between bones and implants, integrating bones and implants securely.

Surface of a DIO RBM implant

Surface of a DIO Hybrid SLA (HSA) implant

Excellent initial fixation

Improve affinity with surrounding soft tissue

Minimize bone absorption around the implant

Minimal inflammatory response to surrounding bones.

Bone formation speed increased up to 49%

Three weeks after implantation, DIO's surface treatment (HSA) shows that bone formation rate is 49% activated compared to DIO's surface treatment(RBM).

For the upper part, a fine roughness of less than 1μm was applied to prevent peri-implantitis. The surface roughness most suitable for osseointegration was applied to the body and apex areas.

Upper

Micro Surface

Body

Macro Surface

Apex

Macro Surface

CONTACT

Dental-Trade Cégcsoport Kft.

1078 Budapest, Marek József u. 31.

Hívja bizalommal értékesítőinket:                                                 ModorGergely gergely.modor@dentaltrade.hu0036703600762 Tarnóczy Zsolt zsolt.tarnoczy@dentaltrade.hu 0036305291705 Rimóczy Gábor gabor.rimoczy@dentaltrade.hu0036703600780 Maitz László laszlo.maitz@dentaltrade.hu 0036305281024